4-element MOX sensor outputting TVOC, eCO2 and AQI; the CCS811 replacement. ENS161 adds a 500-step AQI-S output.
Verdict. Fine as a cheap 'air got worse' trigger. Its eCO2 is a guess from VOCs - never use it in place of a real CO2 sensor.
| Outputs | TVOC, eCO2 (estimate), AQI-UBA; ENS161 AQI-S |
|---|---|
| Interface | I2C 0x52/0x53 |
| Supply | 1.8 V core, boards 3.3-5 V |
| Combo | ENS160+AHT21 boards |
| AliExpress | €6.29 | ENS160+AHT21 combo; +1 k sold· from search results | |
| Botland | €16.5 | DFRobot Fermion ENS160· from shop listing | |
| Pimoroni | €21.9 | Adafruit ENS161· from shop listing |
Many HA forum threads about readings becoming unavailable and warm AHT21 values on combo boards.
“do not measure carbon dioxide.” — atomic14, 2026
“Every few hours the ENS160 stops reading values and output is always” — HA forum, 2024-03