STCC4 thermal-conductivity CO2 sensor breakout
Sensors· Air quality (CO2, VOC, PM)

STCC4 thermal-conductivity CO2 sensor breakout

Sensirion released 2025 current skip budget

Tiny, cheap CO2 sensor (thermal conductivity) used in IKEA ALPSTUGA via SEN63C; noisy and drifty compared with SCD4x/NDIR.

Verdict. Only for tiny or wearable builds where an SCD4x won't fit. For a room monitor an SCD41/43 or Senseair S8 is far more trustworthy.

Specs

Range400-5000 ppm
Accuracy±(100 ppm + 10 %)
Methodthermal conductivity
Needsexternal SHT4x for compensation
InterfaceI2C

Prices

LaskaKit€16.9CZK 412.2LaskaKit STCC4 board, incl. VAT· from shop listing
SparkFun€34.6USD 30.95+VATSTCC4+SHT40 Qwiic· from search results
The Pi Hut€38.9GBP 26.5+VATAdafruit STCC4+SHT41, incl. VAT· from shop listing
  • Very small and low power
  • Cheap (LaskaKit ~€17)
  • Boards include the SHT4x it needs
  • Measured 136 ppm peak-to-peak noise vs 26 ppm for SCD4x
  • Slow drift, strong temperature dependence
  • Needs 12 h burn-in and weekly fresh air

What people say mixed–

AirGradient's 2026 test and HN commenters rate it well below photoacoustic/NDIR sensors; fine as a cheap indicator.

“The STCC4's problem isn't fast noise-it's slow wander.” — AirGradient blog, 2026-03
“No, it is crap. Yes, it is Sensirion, but it uses a thermal conductivity sensor, which is a very indirect method of measuring CO2.” — HN, 2026-07
“the IKEA does have lower accuracy, with ±100 ppm instead of ±30 ppm. From the SEN63C datasheet” — HN, 2026-07